Performed hydraulic modeling in PIPENET for the LP condensate loop from LP Steam Drum (V-904) to Pool Condenser (E-205), covering minimum, normal, and maximum flow cases
•
Extracted and interpreted PIPENET report outputs, including pipe and node summaries, pressure–velocity schematics, friction-loss reports, and multi-case simulation comparisons to support engineering decisions
•
Evaluated upstream and downstream pressure conditions across anti-cavitation control valve HCV-310, validating simulation results against vendor datasheet values and confirming cavitation-free operation
•
Analyzed pump performance (P-911 A/B) by referencing pump curves, computing suction/discharge pressures, differential head, and NPSHa to ensure compliance with equipment design limits
•
Assessed pressure drop and velocity in the 16" suction line and 10" discharge line to verify compliance with hydraulic design criteria
•
Produced client-ready reports with PIPENET schematics (pressure, velocity, diameter) for technical audit and shutdown planning
•
Key Deliverables: Hydraulic calculation reports, PIPENET models, pump & valve evaluation sheets, client review documents